Type: RH28M-2DK.3F.1R
UL Recognized Component E111399 ZA-155
3~ 400V ±10% Y 50Hz P1 0,53kW
0.95A 2750/MIN COSY 0.81 70°C
3~ 460V ±10% Y 60Hz P1 0,86kW
1,25A 3220/MIN COSY 0,87 50°C
IP10 THCL 155
60HZ not voltage controllable
MK092-2DK.10.U
N=62,0
statA=48,7%
Connection cable lateral, 55cm.
Circuit diagram: 1360-159XA Sandwich label
Rating plate: 1x fixed.
Mounting position H/Vu.
Motor protection: thermostatic switch
Operating mode: continuous operation with occasional
starts (S1) according to DIN EN 60034-1:2011-02
Occasional start-up between -40 °C and -25 °C is permissible.
Continuous operation below -25 °C only possible with special
bearings for cold applications on request.
Special impregnation HV.
Balance grade G 6.3
Motor 1-layer coating RAL 7032 (pebble gray)
in resistance class 1 (L-TI-0596)
Impeller made of aluminum, unpainted
All fastening parts secured with Loctite.
With additional clamping bracket for the attachment of the
customer's ground strap/shielding braid.
Ball bearings with long-life grease.
We'll inform you if the price of this product will be changed according to your price alert.